TM 9-2330-359-14&P
4-43. EMERGENCY RELAY VALVE REPLACEMENT.
This Task Covers:
a.
Removal
b.
Installation
Initial Setup:
Equipment Conditions:
Materials/Parts:
Air lines, hoses, and fittings disconnected from
Antiseize tape
emergency relay valve (para 4-35 or 4-36).
Tools/Test Equipment:
General mechanics tool kit
(Item 14, Appendix E)
1.
Turn emergency relay valve (3) counterclockwise
and remove from nipple (2).
2.
Remove nipple (2) from air reservoir (1).
b.
INSTALLATION
1.
Apply antiseize tape to threads of nipple (2).
2.
Install nipple (2) on air reservoir (1).
3.
Turn emergency relay valve (3) clockwise to install on nipple (2).
FOLLOW-ON TASKS:
Connect air lines, hoses, and fittings to emergency relay valve (para 4-35 or 4-36).
Perform air leakage test (para 4-37).
TA508044
4-79