TM 9-2330-238-14
5-34. PANEL STOWAGE CHEST MAINTENANCE (M447C) (Cont).
4.
Inspect chains (15) for damage. If bad, remove rivet (16) and replace as necessary.
5.
Inspect mounting hardware for cracks or stripped threads. Replace defective parts as necessary.
d. ASSEMBLY I
1.
Position two ring assemblies (7) in place on top of panel stowage chest (12) and Install washers (8), new
Iockwashers (9), and nuts (10).
2.
Position lid assembly (26) in place on panel stowage chest (12). Install ten bolts (14), screws (13), and chains
(15) to secure lid assembly (26).
I e.
INSTALLATION I
1.
Using hoist connected to two ring assemblies (7), lift panel stowage chest (12) in place on semitrailer,
2.
Install eight screws (31) and nuts (29) in four angle mounting brackets (30).
3.
Repeat steps 1 and 2 for remaining panel stowage chest (12).
4.
Position two angle mounting brackets (18) in place on semitrailer and install four screws (1 7), new Iockwashers
(19), and nuts (20).
5.
Position two strap assemblies (3 and 11) in place on mounting angles (18) and install two screws (4), new
Iockwashers (5), and nuts (6).
6.
Aline holes in strap assemblies (3 and 11) with holes in panel stowage chests (12) and install six screws (1) and
new Iockwashers (2).
5-98