TM 9-2330-238-14
4-73. HEATER REPLACEMENT (Cont).
3.
Remove heater (12) and rubber strip (23) from deflector assembly (14).
WARNING
Asbestos can be dangerous If you touch It or breathe It. Wear an approved filter mask
and gloves. Never use compressed air or a dry brush to clean components containing
asbestos. Dust may be removed using an industrial-type vacuum cleaner. Clean dust or
mud away from components with water and a wet, soft brush or cloth. Failure to follow
this warning may result In serious illness or death to personnel.
4.
Remove four rivets (22) and asbestos (2 ) from deflector assembly (14). Discard rivets.
5.
Remove two screws (16), washers (17), four screws (15), and two sheet spring nuts (18) from deflector
assembly (14).
d.
INSTALLATION (M447, M447C, AND M750)
1.
Position two sheet spring nuts (18) on deflector assembly (14) and secure with four screws (1 5), and two screws
(16), and washers (17).
WARNING
Asbestos can be dangerous if you touch It or breathe it. Wear an approved filter mask
and gloves. Never use compressed air or a dry brush to clean components containing
asbestos. Dust may be removed using an Industrial-type vacuum cleaner. Clean dust or
mud away from components with water and a wet, soft brush or cloth. Failure to follow
this warning may result In serious Illness or death to personnel.
2.
Position asbestos (21) in place on deflector assembly (14) and secure with four new rivets (22).
TA702055