Figure 62. Hot oil and asphalt piping for single unit Installation.
Figure 6-3. Hot oil and asphalt piping for multiple unit installation.

Technical Manual For Melter, Asphalt Skid Mounted Hot Oil Circulating, 750 Gph Page Navigation
  10    11    12    13    14  15  16    17    18    19    20  
img
.
TM 5-3895-358-14&P
Fig./Index
Part Number
Description
Qty
Number
1 2 3 4 5 6
6-16-2-1
245SS
HOSE END, disconnect, 3 inch (41592) .........................................
2
-2
673-3IN-GAL
COUPLING, pipe, 3 inch (82666) ...................................................
1
-3
3000-9
FLEX-HOSE, asphalt (11740).........................................................
1
-4
179433
TEE, pipe, 3 inch (19207)...............................................................
1
-5
WWP471
PLUG, pipe, 3 inch square head (81348) ........................................
1
-6
MS51884-19ZH
PLUG, pipe, 2-1/2 inch square head (96906) ..................................
2
-7
3000-10
REDUCER TEE (11740).................................................................
2
-8
3000-6
GASKET, 2 inch standard pipe ring (11740) ...................................
4
-9
555-2
FLANGE, blind (14959) (same covers used in Fig. 6-4) ..................
Ref
-10
MS90725-166
SCREW, cap, hex head, 5/8 NC x2-1/2 long (96906) .....................
12
-11
MS51967-20
NUT, plain hex, 5/8 NC(96906).......................................................
12
Figure 6-2. Hot oil and asphalt piping for single unit installation - legend.