TM 5-3825-230-14&P
Table 3-2. Troubleshooting
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
3. ENGINE DOES NOT DEVELOP FULL POWER.
Step 1. Check that the fuel shutoff valve is completely open (para 3-15).
If the valve is open, go to step 2.
Step 2. Check that the air cleaner is not clogged (para 3-7).
If the air cleaner is not clogged, notify the supervisor.
4. EXCESSIVE ENGINE OIL CONSUMPTION.
Check engine for oil leaks or loose lines.
If any leaks or loose lines are found, notify unit maintenance.
Also notify unit maintenance about the oil consumption.
5. ENGINE WILL NOT STOP RUNNING.
Make sure key switch is turned off and the engine cutoff has been pulled (para 2-8b).
Shut off fuel shutoff valve (para 3-15) and notify unit maintenance.
WHEELS, TIRES, AND HUBS
1. WHEEL WOBBLES.
Step 1. Check wheel for loose, missing, or broken lug nuts.
Notify unit maintenance to have lug nuts tightened to torque requirements.
Step 2. Check to see if wheel is bent.
If wheel is bent, notify unit maintenance.
3-10