Sprinkler System Operation. The sprinkler system is used to aid in the sweeping process and to reduce
creation of dust during sweeping. The sprinkler system should not be used in temperatures below 32°F (0°C).
(1)
Remove water tank top (1).
(2)
Fill tank (2) with water and install top (1).
(3)
Open water tank shutoff valve (3) located
beneath water tank.
(4)
Turn key (4) right to first position.
Do not operate sprinkler system
without water in tank or damage to
equipment may result.
(5)
Move sprinkler system toggle switch (5) on
control panel to the ON position.
(6)
Move sprinkler system toggle switch (5) to the
OFF position.
(7)
Turn key (4) fully left to the stop position.
2-19