TM 5-3825-230-14&P
b.
Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a
well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash
immediately with soap and water.
(1)
Apply pipe thread sealing compound to threads of setscrew (10) and plug (5).
(2)
Install setscrew (10) using a 4 mm hex head wrench.
(3)
Install sending unit (9) and pin (8) using a 10 mm and 24 mm open end wrenches.
(4)
Install taper pins (7) using a hammer and drift.
(5)
Install plug (5). and copper washer (6) using a 13 mm open end wrench.
(6)
Install studs (4) using a stud remover/installer.
(7)
Install lever stop (3) and nut (2) using a 13 mm open end wrench.
(8)
Install expansion cap (1) using a 17 mm hex head wrench.
NOTE
Follow-on maintenance: Install crankshaft (para 5-14)
END OF TASK
5-19