• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
QUICK DROP VALVE REPLACEMENT
Figure 1. Top Hydraulic Hose.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  899    900    901    902    903  904  905    906    907    908    909  
img
TM 5-3805-296-23-6
0427
REMOVAL
000427
WARNING
Allow hydraulic system to cool before performing procedure. Hot hydraulic fluid can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills. Failure to follow this warning
may result in injury or death to personnel.
CAUTION
Plug and cap all hydraulic hoses and fittings to prevent contamination.
NOTE
This procedure is for right quick drop valve. Follow same steps for left quick drop valve.
Tag and mark hydraulic hoses and fittings to aid in installation.
Note routing and location of hydraulic hoses to aid in installation.
1. Remove hydraulic hose (Figure 1, Item 1) from fitting (Figure 1, Item 2).
2. Remove O-ring (Figure 1, Item 3) from fitting (Figure 1, Item 2). Discard O-ring.
0427-2