Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes Continued.
APRON LOWER PROPORTIONAL SOLENOID DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  112    113    114    115    116  117  118    119    120    121    122  
img
TM 5-3805-296-23-2
0072
Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes Continued.
072
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Perform Joystick Apron
1277-13 Apron Raise
Lever Sensor Calibration.
Solenoid Out of Calibration
Continued
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick apron lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
Calibration Value Too Low Replace
implement control joystick (WP 0503).
Calibrate joystick (WP 0173).
Calibration Value Too Large
Replace implement control joystick
(WP 0503).
Calibrate joystick (WP 0173).
END OF WORK PACKAGE
0072-20