2-14. PROTECTIVE ENTRANCE (CONT).
ACTION
ITEM
LOCATION
4. Using the old rivet holes in the edge frame (4)
Protective
Entrance
Clamping catch
as a guide, drill two 3/16 inch holes through
fabric (9) and clamping strip (10).
NOTE
Check for and remove any obstructions
before drilling through the clamping strip.
5. Using inch twist drill, carefully debur the
hole in the clamping strip (10).
NOTE
Step 1 applies only to the clamping catch (1)
under the PE door. For the remaining 11
clamping catches (2), begin with step 2.
1. To install the clamping catch (1) directly under
the PE door, replace two bolts (5), Iockwashers
(6), and acorn nuts (7) securing the edge frame
(4) on each side of the clamping catch (1).
2. Install clamping catch (1, 2) over edge frame
(4).
3. Secure clamping catch (1, 2) to edge frame (4)
with two screws (3), washers (8), Iockwashers
(6), and acorn nuts (7).
2-84