2-13. DOME LIGHT
This task covers replacement of:
a. Incandescent lamps
b. Light lens
c. Gasket
Tools
General Mechanics Tool Kit
SC 5180-90-CL-N26
LOCATION
ITEM
ACTION
Dome Light
Incandescent lamps, light
1. Remove six screws (1), light retainer (2), light
lens, and gasket
lens (3) and gasket (4).
2. Remove (red) lamp (s) by pressing in on the
bulb and rotating it counterclockwise. Pull
(red) lamp from socket (6).
3. Remove (white) lamp (7) by pressing in on the
bulb and rotating it counterclockwise. Pull
(white) lamp from socket (8).