NO POWER INDICATION (ALL INDICATOR LIGHTS DO NOT ILLUMINATE WHEN PRESSED TO TEST). - Continued
NO POWER INDICATION (ALL INDICATOR LIGHTS DO NOT ILLUMINATE WHEN PRESSED TO TEST). - Continued

Technical Manual For Collective Protection Equipment, Guardrail With Accessories
Page Navigation
  50    51    52    53    54  55  56    57    58    59    60  
img
. . . . . .
TM
3-4240-309-20&P
3. NO POWER INDICATION (ALL INDICATOR LIGHTS DO NOT ILLUMINATE WHEN PRESSED TO
TEST) (CONT).
Page 2-42
Proceed to page 2-47.
Replace cable A.  Repeat
functional test (p.2-3).
Reconnect cable B.
Replace cable B. Repeat
Replace CCM (p. 2-89).
functional test (p. 2-3).
Repeat functional
test (p. 2-3).
LEGEND
Compartment Control Module
CCM
Feed Thru Elec/Pneu Feed Thru
Power Distribution Unit
PDU
2-46