Section III. MAINTENANCE PROCEDURES
Pressure transmitter MT2

Technical Manual For Compartment Control Module
Page Navigation
  75    76    77    78    79  80  81    82    83    84    85  
img
. . . .
TM 3-4240-302-30&P-1
2-7 COMPARTMENT CONTROL MODULE (CONT).
LOCATION
ITEM
ACTION
Nonmetallic tubing
Replace tubing if torn or broken (item 2,
App B, bulk materials).
Fabricate replacement tubing (3) (item 2,
app B, bulk materials). Cut to same length
as tubing being replaced.
INSTALLATION
1. Install loop clamp (9) on tube (7) if removed.
2. Install hose clamps (3 and 4) on tubes
(7 and 8) if removed.
3. Position pressure switch S6 (5) between tubing
(7 and 8) with switch terminals pointing away
from the thermal flasher DS12 (10) and low
and high markings toward the front panel (11).
4. Install tube (7) on low side of switch and tube
(8) on high side.
5. Slide hose clamps (3 and 4) over tube
connections. Install electrical connectors (6).
Refer to wiring diagram (p. 2-99).
6. Install washer (2) and screw (1).
7. Reassemble CCM (p. 2-77).
2-78