TM 1-1740-204-13&P
b.
Mount the entire assembly (11) in a non-marring vise. Using an adjustable wrench, tighten and orient the quick
disconnect assembly (18) and the shop air regulator (17) in the correct orientation. Using Teflon tape (D1) or
sealant (D2) install low pressure relief valve (10). This reassembles the shop air regulator assembly (11).
c.
Mount the low pressure regulator (9) by the rear forged hex (part of the valve body) in a vise with non-marring
jaws. Slip the end of retaining wire (16) with the large loop over the stem of gauge (14). Using Teflon tape (D1)
or sealant (D2), install gauges (14) and (15) onto the regulator (9) using open end wrenches.
d.
Expand the eyelets of the small loop retainer of retainer wire (16) with a pair of needle nose pliers. Place the
smaller loop retainer over the channel of the low pressure regulator (9) T-handle. Loop the wire loop over the
eyelets of the retainer; then close the eyelets with a pair of needle nose pliers.
e.
Install the T-assembly with the High Pressure Filter (2) onto regulator (9) pipe fittings using Teflon tape (DI) or
sealant (D2). Spin, tighten and orient the assembly (11) on the low pressure regulator (9) . Using Teflon tape
(D1) or sealant (D2) install low pressure relief valve (10).
f.
Secure this assembly to the booster panel by using tube clamp assemblies (7) and (8) and bolts (5) and (6).
g.
Tighten the flare fittings of tubing assemblies (3) and (4). Install Tank Connector Assembly (1) to High Pressure
Filter (2) h. Perform leak check and confidence test procedure per paragraph 2-8.
END OF TASK