1
4
6
3
5
2
TM 9-4940-568-10
2-43
Table 2-3. Operators Level Preventive Maintenance Checks and Services (After) (CONT).
Item
No.
Interval
Item to
Check/
Service
Procedure
Not Fully Mission
Capable If:
39
After
Fuel Water
Separator
(a) Turn drain valve (1) counterclockwise four
complete turns.
(b) Pump fuel pump handle on fuel pump (2).
(c) Drain water until clear fuel is visible, close
drain valve (1).
Flatrack roller must be supported while removing retaining pins or roller may drop
causing injury to personnel.
40
After
Rollers
(a) Hold roller (3) in place. Lift on ring (4),
pull retaining pin (5) out far enough to ensure it
is removeable, then push back in. Perform
same with other pin.
Neither roller functions
correctly.
(b) Ensure that roller (3) will rotate.
(c) Ensure roll pins (6) are not damaged.