10
9
11
12
13
TM 9-4940-568-10
2-97
NOTE
Opening oxygen tank valve and propylene tank valve are the same. Oxygen tank valve
is shown.
(6)
Remove clip (9) and open tank safety cap (10).
(7)
Turn handle (11) counterclockwise and open valve.
(8)
Close tank safety cap (10) and install clip (9).
(9)
Repeat Steps (6) through (8) for propylene tank valve.
NOTE
Open oxygen valve fully. Open proplyene valve only 1/4 turn.
(10)
Adjust oxygen regulator (12) and propylene regulator (13) to desired level. Maximum proplyene
pressure is 10 psi (35 recommended), oxygen 20 40 psi recommended.