STANDARD   AND   FAILSAFE   AIRBRAKE   CHAMBERS   MAINTENANCE
STANDARD   AND   FAlLSAFE   AIRBRAKE   CHAMBERS   MAINTENANCE   (Cont).

TM-9-2330-359-14P Dolly Set Lift Transportable Shelter: M689 M832 M840 Manual
Page Navigation
  117    118    119    120    121  122  123    124    125    126    127  
TM  9-2330-359-14&P 4-42.   STANDARD   AND   FAlLSAFE   AIRBRAKE   CHAMBERS   MAINTENANCE   (Con’t). c. CLEANING AND INSPECTION WARNING Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and gloves, and use only in a well-ventilated area, Avoid contact with skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat. The  solvent’s  flash  point  is  1OO”F-138°F  (38°C-59°C).  If  you  become  dizzy  while using cleaning solvent, immediately get fresh air and medical help. If solvent contacts eyes, Immediately wash your eyes and get medical aid. Clean all parts with dry cleaning solvent and inspect for damage. Replace damaged parts. d . ASSEMBLY Install clevis (7) and jamnut (9) on pushrod (10). TA508042 4-77