  108    109    110    111    112  113  114    115    116    117    118  
TM  9-2330-359-14&P 4-38.   AIR   COUPLING   MAINTENANCE   (M872)   (Con’t). d. INSTALLATION 3. Install nose box cover (2) on nose box (1) with eight  screws  (3). 1. Position air coupling (9), elbow (10), and reducer pipe (11) as an assembly in nose box (1). Install new Iockwasher (6) and nut (5). 2. Apply antiseize tape to threads of air hose (4) and connect air hose to male reducer pipe (11). FOLLOW-ON  TASKS: • Perform air leakage test (para 4-37). TA508034 4-68