AIR   LINES   AND   FlTTINGS   MAINTENANCE   (ALL   EXCEPT   M872A3)
AIR   LINES   AND   FITTINGS   MAINTENANCE   (ALL   EXCEPT   M872A3)   (Cont). - TM-9-2330-359-14P_120

TM-9-2330-359-14P Dolly Set Lift Transportable Shelter: M689 M832 M840 Manual
Page Navigation
  97    98    99    100    101  102  103    104    105    106    107  
TM  9-2330-359-14&P 4-35.   AIR   LINES   AND   FITTINGS   MAINTENANCE   (ALL   EXCEPT   M872A3)   (Con’t). WARNING Compressed air used for clearing restrictions should never exceed 30 psi (207 kPa). Wear protective clothing (goggles/shield, gloves, etc.) and use caution to avoid injury to  personnel. 3. Remove foreign matter from hose/line with compressed air. 4. For metal air lines, remove tube nuts and sleeves from new fitting assemblies and position on ends of tubes. 5. For nylon air lines, remove tube nuts and sleeves from new fitting assemblies and position on ends of nylon tube. Install inserts in each end of tube. TA508028 4-57