TM 9-2330-238-14
4-21. HINGED FLOOR CONDUCTOR PLATE REPLACEMENT (M313).
This Task Covers:
a.
Removal
b.
Installation
Initial Setup:
Equipment Conditions:
l External power supply
Tools/Test Equipment:
Materials/Parts:
l Marker tags (Item 15, Appendix E)
l General mechanics tool kit
1.
Remove two screws (7) and tag and disconnect
two electrical wires (6) from contact assembly (4).
2.
Remove four screws (5), contact assembly (4),
and gasket (3) from conductor plate (l).
3.
Remove four screws (2) and conductor plate (1).
1.
Position conductor plate (1) and install four screws (2).
b. INSTALLATION
2.
Position contact assembly (4) and gasket (3) on conductor plate (1) and
3.
Connect electrical wires (6) to contact assembly (4) with two screws (7).
FOLLOW-ON TASKS:
Connect external power supply cable.
install four screws (5).
Remove tags.
TA701944
4-29