4-103. HYDRAULIC CONTROL VALVE REPLACEMENT (CONT).
b. Installation.
(1)
Install valve (4), three screws (5), and three locknuts (6) using two 9/16 in. open end wrenches.
NOTE
Teflon tape is applied to threads of adapter opposite O-ring side.
(2)
Wrap Teflon tape on threads of adapter (2) .
(3)
Install O-ring (3), adapter (2), and tee pipe (1) using a 1-1/4 in. open end wrench.
NOTE
Follow-on maintenance:
. Install hydraulic filter housing (para 4-108)
. Connect hydraulic hoses to control valve (para 4-105)
END OF TASK