TM 5-3805-296-23-6
0407
INSTALLATION CONTINUED
NOTE
Remove all plugs and caps from hydraulic hoses, lines, and fittings.
Install hydraulic hoses and lines as tagged and marked during removal.
25. Position cushion hitch hydraulic hose (Figure 22, Item 4) on machine.
26. Install new O-ring (Figure 22, Item 6), cushion hitch hydraulic hose (Figure 22, Item 4) and tighten tube nut
(Figure 22, Item 8) on accumulator (Figure 22, Item 7).
27. Install new O-ring (Figure 22, Item 5), cushion hitch hydraulic hose (Figure 22, Item 4), two flange halves
(Figure 22, Item 3), four washers (Figure 22, Item 1), and bolts (Figure 22, Item 2) on leveling valve
(Figure 22, Item 9).
Figure 22. Cushion Hitch Hydraulic Accumulator Hose.