TM 5-3805-296-23-6
0406
REMOVAL CONTINUED
6. Remove plunger (Figure 4, Item 1) from leveling valve (Figure 4, Item 2).
7. Remove three O-rings (Figure 4, Items 3, 4, and 5) from plunger (Figure 4, Item 1). Discard O-rings.
Figure 4. Plunger.
0406
END OF TASK
CLEANING AND INSPECTION
000406
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK