TM 5-3805-296-23-6
0406
REMOVAL CONTINUED
4. Remove two nuts (Figure 2, Item 4), washers (Figure 2, Item 5), bolts (Figure 2, Item 3), washers
(Figure 2, Item 2), clamp (Figure 2, Item 1) and spacer (Figure 2, Item 6) from hydraulic accumulator
(Figure 2, Item 7) and machine.
Figure 2. Clamp.
0406
NOTE
Note location and position of coil to aid in assembly.
5. Remove locknut (Figure 3, Item 1), washer (Figure 3, Item 2), and coil (Figure 3, Item 3) from leveling valve
(Figure 3, Item 4). Discard locknut.
Figure 3. Coil.
0406