TM 5-3805-296-23-5
0346
REMOVAL CONTINUED
CAUTION
Do not disconnect jumper harness from scraper air pressure sensor. Scraper air pressure
sensor damage will occur.
Do not disconnect connector from scraper air pressure sensor. Damage to sensor will
occur.
3. Do not disconnect connector (Figure 2, Item 2) from scraper air pressure sensor (Figure 2, Item 3).
4. Remove scraper air pressure sensor (Figure 2, Item 3) and O-ring (Figure 2, Item 4) from fitting
(Figure 2, Item 5). Discard O-ring.
5. Remove relay (Figure 2, Item 1) and scraper pressure sensor (Figure 2, Item 3) from machine.
Figure 2. Scraper Air Pressure Sensor Relay and Sensor.
0346
END OF TASK
CLEANING AND INSPECTION
000346
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK