TM 5-3805-296-23-5
0332
DISASSEMBLY
000332
NOTE
Note position of fittings to aid in assembly.
1. Remove fitting (Figure 4, Item 1) from holding valve (Figure 4, Item 6).
2. Remove pressure sensor (Figure 4, Item 2) from fitting (Figure 4, Item 3).
3. Remove fitting (Figure 4, Item 3) from fitting (Figure 4, Item 5).
4. Remove fitting (Figure 4, Item 4) from fitting (Figure 4, Item 5).
5. Remove fitting (Figure 4, Item 5) from holding valve (Figure 4, Item 6).
6. Remove fitting (Figure 4, Item 7) from holding valve (Figure 4, Item 6).
Figure 4. Fittings.
0332
END OF TASK
CLEANING AND INSPECTION
000332
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK