TM 5-3805-296-23-5
0331
INSTALLATION
000331
WARNING
Wheels must remain chocked during entire procedure. Failure to follow this warning may
result in injury or death to personnel.
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses as tagged and marked during removal.
1. Apply sealing compound to threads of air hose (Figure 12, Item 4).
2. Install air hose (Figure 12, Item 4) on fitting (Figure 12, Item 6) and tighten tube nut (Figure 12, Item 5).
3. Apply sealing compound to threads of air hose (Figure 12, Item 3).
4. Install air hose (Figure 12, Item 3) on fitting (Figure 12, Item 1) and tighten tube nut (Figure 12, Item 2).
0331-13