3. Install new O-ring (Figure 3, Item 5) on bypass valve (Figure 3, Item 4).
NOTE
Tighten bolts evenly in an alternating pattern.
4. Install bypass valve (Figure 3, Item 4), four washers (Figure 3, Item 3), and bolts (Figure 3, Item 2) on hydraulic
tank (Figure 3, Item 1).
Figure 3. Bypass Valve.
0323
END OF TASK
FOLLOW-ON TASKS
000323
1. Check level of hydraulic oil and add as necessary (WP 0325).
2. Verify correct operation of machine (TM 5-3805-296-10).