TM 5-3805-296-23-5
0322
INSTALLATION CONTINUED
NOTE
Install fittings as noted during removal.
3. Install new O-ring (Figure 8, Item 5) and elbow (Figure 8, Item 2) on implement pilot solenoid pressure
reducing valve (Figure 8, Item 7), tighten jam nut (Figure 8, Item 6).
4. Install new O-ring (Figure 8, Item 4) and test port (Figure 8, Item 3) on elbow (Figure 8, Item 2).
5. Install dust cover (Figure 8, Item 1) on test port (Figure 8, Item 3).
Figure 8. Test Port Elbow.
0322