NOTE
Remove plugs and caps from hydraulic hoses and fittings.
Install hydraulic hoses as tagged and marked during removal.
7. Install new O-ring (Figure 6, Item 12) and hydraulic pilot hose (Figure 6, Item 11). Tighten tube nut
(Figure 6, Item 10) on fitting (Figure 6, Item 2).
8. Install new O-ring (Figure 6, Item 7) and hydraulic pilot hose (Figure 6, Item 9). Tighten tube nut
(Figure 6, Item 8) on fitting (Figure 6, Item 6).
9. Install new O-ring (Figure 6, Item 5) and hydraulic pilot hose (Figure 6, Item 4). Tighten tube nut
(Figure 6, Item 3) on fitting (Figure 6, Item 6).
10. Install new O-ring (Figure 6, Item 15) and hydraulic pilot hose (Figure 6, Item 13). Tighten tube nut
(Figure 6, Item 14) on fitting (Figure 6, Item 1).
Figure 6. Hose Connection.
0318
END OF TASK