TM 5-3805-296-23-2
0109
Table 1. Torque Converter Oil Temperature Too High Continued.
0109
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Verify Malfunction is
Resolved.
Temperature Too High
1. Turn battery disconnect switch to
Continued
ON position and start engine
(TM 5-3805-296-10).
2. On MSD, select Cat Monitoring
System 621G (Figure 3, Item 1).
Figure 3. Accessing Cat Monitoring System ECM Menus.
0109
3. On MSD, select Information
(Figure 4, Item 1), Status
(Figure 4, Item 2), and Status
Group #6 (Figure 4, Item 4).