TM 5-3805-296-23-2
0083
Table 1. 1295 Apron Float Indicator Diagnostic Codes Continued.
083
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Connect jumper wire between
1295-05 Apron Float Lamp
terminal 13 and terminal 14 of
Current Below Normal
connector W-C13 (WP 0012,
Continued
Figure 89).
(WP 0540), measure resistance
Replace transmission/chassis ECM
between connector W-C7
(WP 0495).
terminal 27 and terminal 29
Proceed to Test Step 4.
(WP 0012, Figure 252).
Replace main cab wiring harness
(WP 0505).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1295-5 Apron Float Lamp Current
diagnostic codes (WP 0008).
Below Normal Becomes Inactive
Troubleshooting complete. Proceed to
step 4.
1295-5 Apron Float Lamp Current
Below Normal Remains Active
Repeat troubleshooting from the
beginning.
4. If removed, install lower and upper
plenum on ROPS (WP 0504).
NOTE
1295-06 Apron Float Lamp
Current Above Normal
Always inspect harness connectors that are involved in the circuit. Poor
connections can often be the cause of a problem in an electrical circuit.
Verify that all connections in the circuit are clean and secure and that all
connections are in good condition. If a problem with the connection is
found, correct the problem and verify that this malfunction or diagnostic
code is active before performing this procedure.
Perform open or short-circuit test at each harness connection to identify
the correct harness to replace.
Tag all wiring harnesses to aid in installation.
Perform this test only if condition is active.
0083-8