2-20. AIRFLOW VALVE AND SILENCER ASSEMBLY (CONT).
LOCATION
ITEM
ACTION
Airflow Valve and
Instruction pIate
1. Lift edge of plate (16) with a sharp tool.
Silencer
2. Pull plate completely off the mounting surface.
1. Thoroughly clean mounting surface with dry
cleaning solvent (item 3, app D). Mounting
surface must be free of all contamination such
as oil, grease, dirt or any foreign matter.
2. Activate the back of the plate with dry
cleaning solvent (item 3, app D).
3. Mount the plate and apply pressure to the
plate surface.
4. Spray or brush plate with polyurethane coating
(item 4, app D).