M87 GAS-PARTICULATE FILTER UNIT - Continued
HOUSING UNIT - Continued

Technical Manual For Collective Protection Equipment, Guardrail With Accessories
Page Navigation
  111    112    113    114    115  116  117    118    119    120    121  
img
. . . . . . . . . . . .
TM
3-4240-309-20&P
2-16. HOUSING UNIT
This task covers replacement of:
a. Instruction plates (p. 2-107)
d. Nylon cable (p. 2-110)
b. Seals (p. 2-108)
e. Main fan dust collector (p. 2-111)
c. Protective cap (p. 2-109)
f. Inlet transition (p. 2-114)
Materials/Parts
Tools
Rags (item 6, app D)
General Mechanics Tool Kit
Dry cleaning solvent (item 3, app D)
SC 5180-90-CL-N26
Adhesive (item 1, app D)
References
Brush (item 2, app D)
TM 9-4935-393-14-2
TM 9-1425-391-14
ACTION
ITEM
LOCATION
Instruction plates
Lift edge of plates (1, 2, or 3) with a sharp tool.
Access Hole Frame
Pull plates completely off the mounting surface.
1. Thoroughly clean mounting surface with rags
(item 6, app D) and dry cleaning solvent (item
4, app D). Surface must be free of oil, grease,
dirt, or any foreign matter.
2. peel paper from adhesive backing on plates
(1, 2, or 3).
3. Mount the plates (1, 2, or 3) and apply
pressure to plate surface.
2-107