TM
3-4240-309-20&P
2-14. PROTECTIVE ENTRANCE (CONT).
ACTION
ITEM
LOCATION
Protective
Entrance
K e e p e r plate
5. Using old rivet holes in edge frame (4) as a
guide, drill 3/16 inch holes through fabric (9)
and clamping strip (10).
NOTE
Check the inside of the PE for obstructions
(i.e., protective entrance control module).
Remove if necessary.
6. Using the drill and inch twist drill, carefully
debur the hole in the clamping strip (10).
NOTE
Step 1 applies only to the keeper plate (1)
over the PE door. For the remaining 11
keeper plates (2), begin with step 2.
To install the keeper plate (1) directly over the
1.
PE door, replace two bolts (5), Iockwashers (6),
and acorn nuts (7) on each side of the keeper
plate (1).
Install keeper plate (1, 2) on edge frame (4)
2.
and secure it using two screws (3), lock
washers (6), and acorn nuts (7).