Table 2-1.  Preventive Maintenance Checks and Services for Grounding Kit, MK-2551A/U - Continued
Section IV.  OPERATION UNDER UNUSUAL CONDITIONS - TM-11-5820-1118-12P_18

TM-11-5820-1118-12P Grounding Kit MK-2551A/U (NSN 5820-01-253-1760/RPSTL EIC:N/A) Manual
Page Navigation
  5    6    7    8    9  10  11    12    13    14    15  
SECTION III.  OPERATION UNDER USUAL CONDITIONS 2-1. ASSEMBLY AND PREPARATION FOR USE 2-1.1. Installation. Step 1. Ensure equipment power is not connected. Step 2. Remove Grounding Kit from tool bag. Step 3. Attach terminal lug to grounding stud on Power Entrance Panel of equipment being grounded. Step 4. Lay  cable  around  the  perimeter  of  equipment,    distributing  stakes  evenly  and  creating  an  open-ended ("U" shaped) pattern with no overlapping of cables. Step 5. Begin with the stake closest to the grounding stud.  Pull cable taut.  Twist stake 30° to 45°.  Drive stake until top is flush with ground.  Continue until stakes are all driven into ground. Step 6. Attach jumper cables.  Connect one from front bumper of vehicle to center of cable; connect second from rear bumper of vehicle to end of grounding cable. 2-1.2. Removal Step 1. Disconnect equipment power and discharge supply capacitors. Step 2. Remove jumper cables. 2-4